Sign In | Join Free | My spintoband.com
China Wuhan Qiaoxin Refrigeration Equipment CO., LTD logo
Wuhan Qiaoxin Refrigeration Equipment CO., LTD
Wuhan Qiaoxin Refrigeration Equipment Co., Ltd. Shell and Tube Heat Exchanger Expert
Site Member

8 Years

Home > High Pressure Heat Exchanger >

Oil Cooler Water Cooling Tube Heat Exchanger for Industrial Refrigeration

Wuhan Qiaoxin Refrigeration Equipment CO., LTD

Oil Cooler Water Cooling Tube Heat Exchanger for Industrial Refrigeration

Brand Name : GREEFOUN

Model Number : RE230S10

Certification : CE

Place of Origin : CHINA

MOQ : 1piece

Payment Terms : TT, L/C, Western Union

Supply Ability : 100000pieces/year

Delivery Time : within 15days

Packaging Details : Standard Export Package

Refrigerant : R22/R134a/R407C/R410A

Refrigerating medium : tap/underground/river/sea water, brine, glycol/sulfate solution

Application : Refrigeration industry

Cooling capacity : 18KW~4000KW

Shell material : seamless/304,316Lstainless steel pipe

Type : Shell and tube type

Contact Now

Oil Cooler Water Cooling

Tube Heat Exchanger for Industrial Refrigeration

The oil cooler is a heat exchanger that uses air to cool the hot fluid. And other coolers, there will be rust,

rust occurs mainly because the cooling water contains a lot of calcium, magnesium ions and acid

carbonate, when the cooling water flows through the metal surface, it will produce carbonate; Oxygen in

the cooling water also causes the metal to rust to form rust.

When it produces rust after the heat transfer effect will decline, serious will block the tube so that the heat

loss effect, want to achieve the cooling effect in the shell spray cooling water.

And as the sediment continues to increase, it will also increase the cost of energy, because as long as a

thin layer of scale will increase the fouling part of the equipment operating costs of more than 40%, so the

impact of scaling on heat transfer is huge of.

First, the characteristics:

1, water-cooled oil cooler using water as a medium and oil for heat exchange, the advantage is better

cooling effect, to meet the relatively low oil temperature requirements (the oil temperature can be reduced

to about 40 ℃, the disadvantage is that there must be in the water Of the place to use.

2, air-cooled oil cooler using air as a medium and oil for heat exchange, the advantage is to air as a

cooling source, basically not limited to the use of places, and environmental protection, the disadvantage

is due to the impact of ambient temperature, the higher the temperature , The oil temperature can not be

reduced to the desired temperature (air cooling is generally difficult to reduce the oil temperature only

higher than the ambient temperature of 5 ~ 10 ℃).


CONDENSER SERIES SINGLE SYSTEM

CAPACITY: 110RT TO 200RT

Model Refrig. ton (RT) Refrig. ton (104kcal/h) Dimension (mm) Weight (kg) Max. water flow
D T1 T A C E H1 H2
QXC110S12A 110 41.58 325 2500 2966 150 406 180 350 240 411 83.5
QXC120S14A 120 45.36 355 2500 3023 150 440 200 400 290 490 91
QXC130S14A 130 49.15 355 2500 3023 150 440 200 400 290 506 98.5
QXC140S14A 140 52.92 355 2500 3023 150 440 200 400 290 521 106
QXC150S14A 150 56.70 355 2500 3023 150 440 200 400 290 536 113.5
QXC160S16A 160 60.48 426 2500 2952 150 530 260 310 310 637 120.6
QXC180S16A 180 68.04 426 2500 2952 150 530 260 310 310 667 135.5
QXC200S16A 200 75.60 426 2500 2952 150 530 260 310 310 697 150.8

Model S (Vent)

P (fluoride inlet)

Copper pipe diameter (inch)

L(fluoride outlet)

Copper pipe diameter (inch)

W (standard port) W (optional port)
FPT(inner pipe thread) Male flange Male flange
QXC110S12A 3/8 3-1/8 1-5/8 DN100 DN100
QXC120S14A 3/8 3-1/8 1-5/8 DN100 DN100
QXC130S14A 3/8 3-1/8 1-5/8 DN100 DN100
QXC140S14A 3/8 3-1/8 1-5/8 DN100 DN100
QXC150S14A 3/8 3-1/8 1-5/8 DN100 DN125
QXC160S16A 3/8 3-1/8 1-5/8 DN125 DN125
QXC180S16A 3/8 3-1/8 1-5/8 DN125 DN125
QXC200S16A 3/8 3-1/8 1-5/8 DN125 DN125

WATER TO WATER HEAT EXCHANGER

CAPACITY: 100KW TO 400KW

Model Capacity (KW) Dimension (mm) Weight (kg)
D T1 T A C E F G
QXWW8S6 100 168 762 858 80 185 92 80 0 51
QXWW15S6 200 168 1270 1366 80 185 92 80 0 78
QXWW20S8 300 219 1270 1380 100 238 113 80 30/0 118
QXWW30S8 400 219 1270 1380 100 238 113 80 30/0 131

Model W1 W2
Specification Connection type Specification Connection type
QXWW8S6 G1-1/2 internal pipe thread G1-1/2 internal pipe thread
QXWW15S6 G1-1/2 internal pipe thread G1-1/2 internal pipe thread
QXWW20S8 G2 internal pipe thread G2 internal pipe thread
QXWW30S8 G2-1/2 internal pipe thread G2-1/2 internal pipe thread

COMPANY IMAGE

Oil Cooler Water Cooling Tube Heat Exchanger for Industrial Refrigeration

COOPERATED CLENTS
Oil Cooler Water Cooling Tube Heat Exchanger for Industrial Refrigeration


Product Tags:

water cooled heat exchanger

      

shell type heat exchanger

      
Wholesale Oil Cooler Water Cooling Tube Heat Exchanger for Industrial Refrigeration from china suppliers

Oil Cooler Water Cooling Tube Heat Exchanger for Industrial Refrigeration Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Wuhan Qiaoxin Refrigeration Equipment CO., LTD
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0